{"id":4555,"date":"2026-06-16T12:37:49","date_gmt":"2026-06-16T09:37:49","guid":{"rendered":"https:\/\/demo.erayonetim.com\/?post_type=event&#038;p=4555"},"modified":"2026-07-02T14:31:10","modified_gmt":"2026-07-02T11:31:10","slug":"osteosynthesis-product-tests","status":"publish","type":"event","link":"https:\/\/demo.erayonetim.com\/en\/hizmetlerimiz\/osteosentez-urun-testleri\/","title":{"rendered":"Osteosynthesis Product Testing"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row row top-row vc_row-o-equal-height vc_row-flex wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t<h2 style=\"color: #0c3261; font-weight: 800; margin-bottom: 25px;\">OSTEOSYNTHESIS PRODUCT TESTING<\/h2>\n<p style=\"text-align: justify; line-height: 1.8; color: #444;\">In bone fractures, the fractured areas need to be held together for healing. Plates, screws, pins, wires, external fixators, and biodegradable plates and screws can be used to hold the fractured area together. The strength of the osteosynthesis products used in the body is crucial for complete healing and the preservation of patient health.<\/p>\n<p style=\"text-align: justify; line-height: 1.8; color: #444;\">International standards and regulations have published test standards to determine the durability of the products used. The main mechanical tests we perform, adhering to the ISO 17025 standard, are as follows:<\/p>\n<ul style=\"list-style: none; padding: 0; line-height: 2.2; color: #444; font-size: 15px;\">\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Flat Bone Plates: <strong>ASTM F382<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Angled Orthopedic Fixation: <strong>ASTM F384<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Intramedullary Devices: <strong>ASTM F1264<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> External Fixators: <strong>ASTM F1541<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Biodegradable Plates and Screws: <strong>ASTM F2502<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Bone Screws: <strong>ASTM F543<\/strong><\/li>\n<\/ul>\n\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6 vc_custom_image\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-plak-vida-77-400x600.jpg\" width=\"400\" height=\"600\" alt=\"era-plate-screw-77\" title=\"era-plate-screw-77\" loading=\"lazy\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t<table style=\"width: 100%; border-collapse: collapse; border: 1px solid #ddd; margin-top: 20px;\">\n<tbody>\n<tr style=\"background-color: #0c3261; color: #fff;\">\n<th style=\"padding: 15px; border: 1px solid #ddd;\">SAMPLE<\/th>\n<th style=\"padding: 15px; border: 1px solid #ddd;\">STANDARD<\/th>\n<th style=\"padding: 15px; border: 1px solid #ddd;\">EXPLANATION<\/th>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">RECORD<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F382<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Specification and Test Method for Metallic Bone Plates<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ANGLED RECORD<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F384<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">BONE SCREWS<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F543<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Specification and Test Methods for Metallic Medical Bone Screws<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">METALLIC BONE STAPLES<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F564<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Specification and Test Methods for Metallic Bone Staples<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">INTRAMEDULAR NAIL AND SCREW<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F1264<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">EXTERNAL FIXATORS<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F1541<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Specification and Test Methods for External Skeletal Fixation Devices<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">BIODEGRADABLE PLATE AND SCREW<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F2502<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-plak-vida-773A-400x600.jpg\" width=\"400\" height=\"600\" alt=\"era-plate-screw-773A\" title=\"era-plate-screw-773A\" loading=\"lazy\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-plak-vida-77-400x600.jpg\" width=\"400\" height=\"600\" alt=\"era-plate-screw-77\" title=\"era-plate-screw-77\" loading=\"lazy\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Kemik k\u0131r\u0131klar\u0131nda k\u0131r\u0131lan yerlerin iyile\u015fmesi i\u00e7in k\u0131r\u0131lan b\u00f6lgelerin bir arada tutulmas\u0131 gerekmektedir.<\/p>","protected":false},"featured_media":4632,"menu_order":0,"template":"","class_list":["post-4555","event","type-event","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/event\/4555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/event"}],"about":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/types\/event"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/media\/4632"}],"wp:attachment":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/media?parent=4555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}