{"id":4570,"date":"2026-06-16T13:30:51","date_gmt":"2026-06-16T10:30:51","guid":{"rendered":"https:\/\/demo.erayonetim.com\/?post_type=event&#038;p=4570"},"modified":"2026-07-02T14:28:54","modified_gmt":"2026-07-02T11:28:54","slug":"knee-prosthesis-testing","status":"publish","type":"event","link":"https:\/\/demo.erayonetim.com\/en\/hizmetlerimiz\/diz-protezi-testleri\/","title":{"rendered":"Knee replacement tests"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row row top-row vc_row-o-equal-height vc_row-flex wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t<h2 style=\"color: #0c3261; font-weight: 800; margin-bottom: 25px;\">KNEE PROSTHESIS TESTS<\/h2>\n<p style=\"text-align: justify; line-height: 1.8; color: #444;\">Total knee replacements consist of three parts, and for product safety, mechanical testing must be performed in accordance with international standards. The main parts of a total knee replacement can be tested individually, or all parts can be tested simultaneously.<\/p>\n<p style=\"text-align: justify; line-height: 1.8; color: #444;\">Our main testing methods, which are included in our accreditation scope and ensure the safety of your prostheses, are as follows:<\/p>\n<ul style=\"list-style: none; padding: 0; line-height: 2.2; color: #444; font-size: 15px;\">\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Tibial Tray Fatigue Test: <strong>ASTM F1800 \/ ISO 14879<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Unicondylar Tibia Test: <strong>ASTM F3140<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Insert Wear and Movement Tests: <strong>ASTM F2777<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Mobile Bearing Mechanical Tests: <strong>ASTM F2722 \/ F2723 \/ F2724<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Total Knee Implant Tests: <strong>ASTM F1223 \/ ISO 7207-2<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Femoral Component Fatigue Test: <strong>ASTM F3210-22e1<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Knee Prosthesis Wear Test: <strong>ISO 14242-2<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Knee Prosthesis Wear Test (Parameters): <strong>ISO 14242-3<\/strong><\/li>\n<\/ul>\n\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6 vc_custom_image\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-diz-161-400x600.jpg\" width=\"400\" height=\"600\" alt=\"era-diz-161\" title=\"era-diz-161\" loading=\"lazy\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t<table style=\"width: 100%; border-collapse: collapse; border: 1px solid #ddd; margin-top: 20px;\">\n<tbody>\n<tr style=\"background-color: #0c3261; color: #fff;\">\n<th style=\"padding: 15px; border: 1px solid #ddd;\">SAMPLE<\/th>\n<th style=\"padding: 15px; border: 1px solid #ddd;\">STANDARD<\/th>\n<th style=\"padding: 15px; border: 1px solid #ddd;\">EXPLANATION<\/th>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">KNEE PROSTHESIS TIBIAL TRAY<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F1800<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Practice for Cyclic Fatigue Testing of Metal Tibial Tray Components of Total Knee Joint Replacements<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">KNEE PROSTHESIS UNICONDULARY TIBIA<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F3140<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Cyclic Fatigue Testing of Metal Tibial Tray Components of Unicondylar Knee Joint Replacements<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">KNEE PROSTHESIS INSERT<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F2777<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Evaluating Knee Bearing (Tibial Insert) Endurance and Deformation Under High Flexion<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">KNEE PROSTHESIS MOBILE BEARING<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F2722<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Practice for Evaluating Mobile Bearing Knee Tibial Baseplate Rotational Stops<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">KNEE PROSTHESIS MOBILE BEARING<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F2723<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Evaluating Mobile Bearing Knee Tibial Baseplate\/Bearing Resistance to Dynamic Disassociation<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">KNEE PROSTHESIS MOBILE BEARING<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F2724<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Evaluating Mobile Bearing Knee Dislocation<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">TOTAL KNEE IMPLANT<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F1223<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Determination of Total Knee Replacement Constraint<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">TOTAL KNEE IMPLANT<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ISO 7207-2<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Implants for surgery \u2014 Components for partial and total knee joint prostheses Part 2<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">TOTAL KNEE FEMORAL COMPONENT<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F3210<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Fatigue Testing of Total Knee Femoral Components Under Closing Conditions<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">TOTAL KNEE JOINT PROSTHESIS<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ISO 14242-2<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Implants for surgery \u2014 Wear of total knee-joint prostheses<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">TOTAL KNEE JOINT PROSTHESIS<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ISO 14242-3<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Implants for surgery \u2014 Wear of total knee-joint prostheses Part 3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"beyaz-golgeli-kutu vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\"><div class=\"vc_row wpb_row vc_inner row vc_row-o-content-middle vc_row-flex\"><div class=\"vc_column_container col-md-6\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-diz-161-400x600.jpg\" width=\"400\" height=\"600\" alt=\"era-diz-161\" title=\"era-diz-161\" loading=\"lazy\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><div class=\"vc_column_container col-md-6\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-diz-171-400x600.jpg\" width=\"400\" height=\"600\" alt=\"era-diz-171\" title=\"era-diz-171\" loading=\"lazy\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Total Diz Protezleri 3 par\u00e7adan olu\u015fmaktad\u0131r ve \u00fcr\u00fcn g\u00fcvenli\u011fi i\u00e7in uluslararas\u0131 standartlara ba\u011fl\u0131 kalarak mekanik testlerinin yap\u0131lmas\u0131 gerekmektedir.<\/p>","protected":false},"featured_media":4628,"menu_order":0,"template":"","class_list":["post-4570","event","type-event","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/event\/4570","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/event"}],"about":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/types\/event"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/media\/4628"}],"wp:attachment":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/media?parent=4570"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}