{"id":4648,"date":"2026-07-02T12:02:02","date_gmt":"2026-07-02T09:02:02","guid":{"rendered":"https:\/\/demo.erayonetim.com\/?post_type=event&#038;p=4648"},"modified":"2026-07-08T19:40:19","modified_gmt":"2026-07-08T16:40:19","slug":"coating-tests","status":"publish","type":"event","link":"https:\/\/demo.erayonetim.com\/en\/hizmetlerimiz\/kaplama-testleri\/","title":{"rendered":"Coating Tests"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row row top-row vc_row-o-equal-height vc_row-flex wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t<h2 style=\"color: #0c3261; font-weight: 800; margin-bottom: 25px;\">COATING TESTS<\/h2>\n<p style=\"text-align: justify; line-height: 1.8; color: #444;\">Determining the adhesion strength and fatigue resistance of calcium phosphate and metallic coatings applied to improve the surface performance of medical devices is of critical importance. At ERA Management laboratories, the mechanical integrity of these coatings under clinical conditions is analyzed in accordance with international standards.<\/p>\n<p style=\"text-align: justify; line-height: 1.8; color: #444;\">Our main test methods included in our accreditation scope, which verify your coating performance, are as follows:<\/p>\n<ul style=\"list-style: none; padding: 0; line-height: 2.2; color: #444; font-size: 15px;\">\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Coating Shear Test: <strong>ASTM F1044<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Coating Tension Test: <strong>ASTM F1147<\/strong><\/li>\n<li><i class=\"fa fa-check-circle\" style=\"color: #0088cc; margin-right: 10px;\"><\/i> Coating Fatigue Test: <strong>ASTM F1160<\/strong><\/li>\n<\/ul>\n\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><div class=\"beyaz-golgeli-kutu vc_column_container col-md-6 vc_custom_image\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/kaplama-400x600.jpg\" width=\"400\" height=\"600\" alt=\"covering\" title=\"covering\" loading=\"lazy\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t<table style=\"width: 100%; border-collapse: collapse; border: 1px solid #ddd; margin-top: 20px;\">\n<tbody>\n<tr style=\"background-color: #0c3261; color: #fff;\">\n<th style=\"padding: 15px; border: 1px solid #ddd;\">SAMPLE<\/th>\n<th style=\"padding: 15px; border: 1px solid #ddd;\">STANDARD<\/th>\n<th style=\"padding: 15px; border: 1px solid #ddd;\">EXPLANATION<\/th>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">COATED SAMPLE<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F1044<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Shear Testing of Calcium Phosphate Coatings and Metallic Coatings<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">COATED SAMPLE<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F1147<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Tension Testing of Calcium Phosphate and Metallic Coatings<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">COATED SAMPLE<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">ASTM F1160<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Coatings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_text_column wpb_content_element wpb_custom_7c91d232724f73626cc933bd95b25ff0\" >\r\n\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><div class=\"vc_row wpb_row row top-row wpb_custom_034b39d9bc6c6b310d69e39f0ccf274f\"><div class=\"beyaz-golgeli-kutu vc_column_container col-md-12\"><div class=\"wpb_wrapper vc_column-inner\"><div class=\"vc_row wpb_row vc_inner row vc_row-o-content-middle vc_row-flex\"><div class=\"vc_column_container col-md-4\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/kaplama.jpg\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"covering\" srcset=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/kaplama.jpg 800w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/kaplama-768x576.jpg 768w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/kaplama-463x348.jpg 463w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/kaplama-640x480.jpg 640w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/kaplama-400x300.jpg 400w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><div class=\"vc_column_container col-md-4\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"683\" height=\"1024\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-test-683x1024.jpg\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"era-astm-f3210-test\" srcset=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-test-683x1024.jpg 683w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-test-640x960.jpg 640w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-test-400x600.jpg 400w\" sizes=\"auto, (max-width: 683px) 100vw, 683px\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><div class=\"vc_column_container col-md-4\"><div class=\"wpb_wrapper vc_column-inner\">\r\n\t<div class=\"wpb_single_image wpb_content_element vc_align_center wpb_content_element  wpb_custom_81a4f7ef9830bf958462581aa01150fb\"><div class=\"wpb_wrapper\">\r\n\t\t\t\r\n\t\t\t<div class=\"vc_single_image-wrapper vc_box_shadow_border  vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-h-1024x683.jpg\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"era-astm-f3210-h\" srcset=\"https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-h-1024x683.jpg 1024w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-h-768x512.jpg 768w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-h-640x427.jpg 640w, https:\/\/demo.erayonetim.com\/wp-content\/uploads\/era-astm-f3210-h-400x267.jpg 400w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/div>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>T\u0131bbi cihaz kaplamalar\u0131 i\u00e7in gerekli t\u00fcm performans ve do\u011frulama testlerini yap\u0131yoruz.<\/p>","protected":false},"featured_media":4630,"menu_order":0,"template":"","class_list":["post-4648","event","type-event","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/event\/4648","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/event"}],"about":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/types\/event"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/media\/4630"}],"wp:attachment":[{"href":"https:\/\/demo.erayonetim.com\/en\/wp-json\/wp\/v2\/media?parent=4648"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}